Panasonic A6 AC Servo Motor System Configuration and Wiring -- 2.2.1 Driver and List of Applicable Peripheral Equipments

Abstract

The peripheral equipments will work with the Panasonic A6 series of servo motor and driver in the machineries and automation system, here in this chapter you'll have a list of the applicable peripheral equipments for the Panasonic A6 series of AC motor driver.


List of Peripheral Equipments

Driver Voltage *1 Rated output Required Power (at the rated load) Circuit breaker (rated current) Noise filter (Single phase/3-phase) Surge absorber (Single phase/3-phase) Noise filter for signal Rated operating current of magnetic (Contactor Contact configuration *2)
MADL☐☐☐☐☐ Single phase, 100 V 50 W to 100 W approx, 0.4 kVA 10 A DV0P4170 DV0P4190 DV0P1460 20 A (3P+1a)
Single/3-phase, 200 V 50 W to 200 W approx. 0.5 kVA DV0P4170/DV0PM20042 DV0P4190/DV0P1450
MBDL☐☐☐☐☐ Single 100 V 200 W approx. 0.5 kVA DV0P4170 DV0P4190
Single/3-phase, 200 V 400 W approx. 0.9 kVA DV0P4170/DV0PM20042 DV0P4190/DV0P1450
MCDL☐☐☐☐☐ Single 100 V 400 W approx. 0.9kVA 15A DV0PM20042 DV0P4190
Single/3-phase, 200V 750 W approx. 1.3kVA DV0P4190/DV0P1450
MDDL☐☐☐☐☐ 3-phase, 200V 1.0 kW approx. 1.8 kVA 20 A DV0P4220 30 A (3P+1a)
0.9 kW approx. 1.8 kVA
1.0 kW approx. 1.8 kVA
1.5 kW approx. 2.3 kVA
MEDL☐☐☐☐☐ 3-phase, 200V 2.0 kW approx. 3.3 kVA 30 A DV0PM20043 DV0P1450 DV0P1460 RJ8035 (Recommended component *4) 60 A (3P+1a)
2.5 kW approx. 3.8 kVA
MFDL☐☐☐☐☐ 3-phase, 200 V 2.0 kW approx. 3.8 kVA 50 A DV0P3410 DV0P1450 DV0P1460 RJ8035 60 A (3P+1a)
3.0 kW approx. 4.5 kVA
4.0 kW approx. 6.0 kVA 100 A (3P+1a)
4.5 kW approx. 6.8 kVA
5.0 kW approx. 7.5 kVA

List of Applicable diameter cables

Driver Voltage *1 Rated output Required Power (at the rated load) Diameter and withstand voltage of main circuit cable Crimp terminal for main circuit terminal block Diameter and withstand voltage of control power supply cable Crimp terminal for control power supply terminal block Diameter and withstand voltage of motor cable *4 Diameter and withstand voltage of brake cable
MADL☐☐☐☐☐ Single phase, 100 V 50 W to 100 W approx. 0.4 kVA 0.75mm2/AWG18 600 VAC or more Connection to exclusive connector 0.75mm2/AWG18 600 VAC or more Connection to exclusive connector 0.75mm2/AWG18 600 VAC or more 0.28mm2/AWG22 to 0.75mm2/AWG18 100 VAC or more
Single/3-phase, 200 V 50 W to 200 W approx. 0.5 kVA
MBDL☐☐☐☐☐ Single phase, 100 V 200 W approx. 0.5 kVA
Single/3-phase, 200 V 400 W approx. 0.9 kVA
MCDL☐☐☐☐☐ Single phase, 100 V 400 W approx.0.9 kVA
Single/3-phase, 200 V 750 W approx. 1.8 kWA
MDDL☐☐☐☐☐ Single/3-phase, 200 V 0.9 kW approx. 2.3 kVA 2.0 mm2/AWG14 600 VAC or more 2.0 mm2/AWG14 600 VAC or more 0.75 mm2/AWG18 100 VAC or more
1.0 kW approx. 2.4 kVA
1.5 kW approx. 2.9 kVA

Note → When use the external regenerative resistor of the option, use the cable with the same diameter as the main circuit cable.


Related page → Noise filter ...P. 7-108 Surge absorber ...P. 7-110 Ferrite coil ...P. 7-111 Motor/brake connector ...P. 2-28

Driver Voltage *1 Rated output Required Power (at the rated load) Diameter and withstand voltage of main circuit cable Crimp terminal for main circuit terminal block Diameter and withstand voltage of control power supply cable Crimp terminal for control power supply terminal block Diameter and withstand voltage of motor cable *4 Diameter and withstand voltage of brake cable
MEDL☐☐☐☐☐ 3-phase, 200 V 2.0 kW approx. 3.3 kVA 2.0 mm2/AWG14 600 VAC or more Connection to exclusive connector 0.75mm2/AWG18 600 VAC or more Connection to exclusive connector 2.0 mm2/AWG14 600 VAC or more 0.75mm 2/AWG18 100 VAC or more
2.4 kW approx. 4.5 kVA
MFDL☐☐☐☐☐ 3-phase, 200 V 3.0 kW approx. 4.5 kVA 3.5 mm2/AWG 12 600 VAC or more Panasonic A6

Terminal block M5

Panasonic A6

Terminal block M5

3.5mm 2/AWG12 600 VAC or more

*1 Select peripheral equipments for single/3phase common specification according to the power source.
*2 For the external dynamic brake resistor, use the magnetic contactor with the same rating as that for the main circuit.
*3 When use the external regenerative resistor of the option (DV0PM20058, DV0PM20059), use the cable with the same diameter as the main circuit cable.
*4 Use these products to suit a standard.

  • About circuit breaker and magnetic contactor

    To comply to EC directives, install a circuit breaker between the power and the noise filter without fail, and the circuit breaker should conform to IEC Standards and UL recognized (Listed and Panasonic A6 marked).
    Suitable for use on a circuit capable of deivering not more than 5,000 Arms symmetrical amperes, below the maximum input voltage of the product.
    Remarks → Select a circuit breaker and noise filter which match to the capacity of power supply (including a load condition).
  • Terminal block and protective ground terminals
    • Use a copper conductor cables with temperature rating of 75 °C or higher.
    • Use the attached exclusive connector for A to E-frame, and maintain the peeled off length of 8 to 9 mm. (Refer to P. 2-31)
  • Fastening torque list (Terminal block screw/Terminal over fastening screw)
    Driver Terminal block screw Terminal cover fastening screw
    Frame Terminal name Norminal size Fastening torque (N•m)Note 1 Nominal size Fastening torque (N•m)Note 1
    F L1, L2, L3, L1C, L2C, P, RB, B, N, U, V, W M5 1.0 to 1.7 M3 0.19 to 0.21
  • Fastening torque list (Ground terminal screw/Connector to host controller (X4))
    Driver frame Terminal block screw Connector to host controller (X4)
    Nominal size Fastening torque (N•m)Note 1 Nominal size Fastening torque (N•m)Note 1
    A to E M4 0.7 to 0.8 M2.6 0.3 to 0.35
    F M5 1.4 to 1.6

    Caution → Note:1

    • Applying fastening torque larger than the maximum value may result in damage to the product.
    • Do not turn on power without tightening all terminalk block screws properly.
    • Do not turn on power without tightening all the terminal block screws properly, otherwise, loose contacts may generate heat (smoking, firing).
    • To check for looseness, conduct periodic inspection of fastening torque once a year.
    Be sure to conduct wiring properly and securely. Insecure or improper wiring may cuase the motor running out of control or being damaged from overheating. In addition, pay attention not to allow conductive materials, such as wire chips, entering the driver during the installation and wiring.