Keywords:PETRI DISH PACKING SYSTEM, PETRI DISH INJECTION MOLDING SOLUTIONS
The main page is the human/machine interface of the SWITEK side entry petri dish packing system after power on, where the operator of the petri dish packing system start the programming, the parameters setting of petri dish packing system. Here in this chapter we'll introduce the function of the buttons.
| No. | Description |
|---|---|
| 1 | Mold Open (OFF) |
| 2 | Mold Close (OFF) |
| 3 | Mold Close Finished (OFF) |
| 4 | Change Label (OFF) |
| 5 | Start (OFF) |
| 6 | Pause (OFF) |
| 7 | Emergency Stop (OFF) |
| 8 | Manual (OFF) |
| 9 | Origin (ON) |
| 10 | Auto-display |
| 11 | Origin Display |
| 12 | Crurrently Stacked |
| 13 | The Current Position of Axis |
| 14 | Auto Mode |
| 15 | Manual Mode |
| 16 | System Parameters |
| 17 | Position Setting |
| 18 | Position Interface |
| 19 | Alarm Interface |
| 20 | IO Monitor |
SW6308D-20
Unit: mm
| X1 | X2 | X3 | X4 | Y | YM1 | YM2 | Z | L | W | H | Payload | 740 | 640 | 140 | 415 | 800 | 235 | 565 | 1350 | 2320 | 1500 | 1460 | 3kg |
|---|
EOAT Assembly Demonstration -- Two Cavities Parts Picking EOAT with Runner Cutting by Air Nipper
Product Descriptions
Bom List
| Product Name | PN # | Model | Quantity |
|---|---|---|---|
| Sus Tube | 4.Y00021 | PST12-1500 | 2 |
| Air Nipper | 1.Y00004 | GT-NY25 | 2 |
| Straight Blades for Plastic | 1.Y00037 | NY25AJ | 2 |
| Fixing Block | 7.Y00633 | SCE2-25 | 2 |
| Tube Plugs | 1.Y03638 | PST12-1500 | 11 |
| Cross Connector | 7.Y00027 | SMBT-2012 | 2 |
| Access Robot Bracket | 7.Y00002 | SMBH1-12M6 | 6 |
| L-Type Thread Hose Fitting | 1.Y02809 | APL6-M5 | 3 |
| Slide Bracket | 7.Y00004 | SCF4-1240W16 | 7 |
| Slide Bracket | 7.Y00001 | SMBS-12T16 | 7 |
| Sprue Gripper | 8.Y00091 | GR12-12-CN | 1 |
| Cross Connector | 7.Y00020 | SMBT-1212 | 1 |
How is the SWITEK IML System for 2 Cavities Butter Box with 2 Lables Designed?
IML Containers with 2 lables will provide more space for the dairy products producers to design their pattern and provide more detailed description of their products, but with one more label it'll make the design of the IML system much more complex. How would be the two labels to be put into the mold and what would be the recommendation of such an IML system?
SWITEK has both solutions of 2 cavities IML solutions for oval shpe box and 4 cavities IML solutions for round cups with 2 labels. The difference of the 2 labels IML solutions of wrap + bottom labeling will request more space for the magazine layout design. Both the labels would be put into the cavities at the movable part of the platen with the parts to be picked from the fixed part of the platen.
Since the structure of the magazine for the IML containers with two labels is much more complex than that of wrap labeling only, the best solution is to have a turn-key IML solutions from SWITEK Automation so we can have the robot and the injection mould well tested together before delivery to ensure that the system which you received is ready to work. For more details about a turn-key IML solutions please contact Adams from SWITEK Automation, you're personal advisor of IML Soutions integration.